UPS battery replacement and repair in Riga — SATER
SATER service centre at Silmaču iela 6, Riga (LV-1012) performs UPS (uninterruptible power supply) battery replacement and charging circuit repair. Since 1993 — more than 30 years of electronics experience — we have serviced thousands of UPS units across home, office and server-room segments. Our…
SATER service centre at Silmaču iela 6, Riga (LV-1012) performs UPS (uninterruptible power supply) battery replacement and charging circuit repair. Since 1993 — more than 30 years of electronics experience — we have serviced thousands of UPS units across home, office and server-room segments. Our customers rate us 4.3 stars across 186 Google reviews. UPS batteries — whether traditional SLA (Sealed Lead-Acid), AGM (Absorbent Glass Mat) or newer Li-Ion — are consumable components with a limited lifespan, typically 3–5 years. When a battery reaches the end of its life cycle, the UPS can no longer sustain an adequate runtime during a power outage, begins beeping continuously, or shuts down altogether. We replace batteries for all mainstream UPS brands — APC Back-UPS (BX, BE, BR series), APC Smart-UPS (SMT, SMC), Eaton 5E/5P/9SX, CyberPower UT/VP, PowerWalker VI series and Vertiv Liebert. We also diagnose and repair UPS charging circuits when the problem goes beyond the battery itself. Battery replacement carries a 6-month warranty; charging circuit repairs are covered for 3 months. Diagnostics are performed on the spot — the device must be brought in person. Call +371 67377002 or visit us on weekdays and Saturdays from 09:00 to 16:00.
Popular models we repair
- APC Back-UPS BX (BX750MI, BX1400UI, BX1600MI)
- APC Back-UPS BE / BR (BE700G, BR1500GI)
- APC Smart-UPS SMT (SMT750I, SMT1500I, SMT2200I)
- APC Smart-UPS SMC (SMC1000I, SMC1500I)
- Eaton 5E / 5P / 9SX series
- CyberPower UT / VP series
- PowerWalker VI series (VI 850, VI 1500)
- Vertiv Liebert (GXT5, PSI5)
Common problems we fix
- Battery end of life (3–5 year cycle) — UPS no longer provides runtime
- UPS beeping continuously — battery replacement indicator active
- UPS no longer holds load during outage — equipment shuts off instantly
- Charging circuit failure — battery will not charge or charges only partially
- Swollen SLA/AGM battery — electrolyte leaked, case deformed
Detailed problem guides
Pick a symptom — we walk through the causes, what you can check yourself, and when to bring it in.
- Won't chargeBattery won't charge — repair and rebuild in Riga
- Dies quicklyBattery dies quickly — diagnostics and rebuild in Riga
- Not detectedBattery not detected — diagnostics and repair in Riga
- OverheatingBattery overheating — diagnostics and safe repair in Riga
- Drains fastBattery drains fast — diagnostics and repair in Riga
UPS battery replacement: SLA, AGM, and Li-Ion options
Most home and office UPS units use sealed lead-acid (SLA) or absorbent glass mat (AGM) batteries. These batteries are reliable and affordable, but their lifespan is limited — typically 3–5 years depending on ambient temperature. Higher temperatures accelerate degradation: every 10°C above 25°C cuts battery life by roughly 50%. This is why UPS batteries in air-conditioned server rooms last longer than those in an office without climate control.
At our service centre at Silmaču iela 6 we replace SLA and AGM batteries for all mainstream UPS brands. An APC Back-UPS BX series typically requires a single 12V 7Ah or 12V 9Ah battery, while the APC Smart-UPS SMT1500I uses two 12V 12Ah batteries wired in series (24V). Larger Eaton and Vertiv systems may have 4–8 battery blocks with a total voltage up to 192V. We always fit batteries with matching or higher capacity, verify the charge voltage (typically 13.6–13.8V per 12V block) and run a load test after replacement. Some newer UPS systems also support Li-Ion battery kits that offer two to three times longer service life and lower weight — we advise on this option during diagnostics.
UPS charging circuit diagnostics and repair
The UPS charging circuit is a critical component that keeps the battery at full readiness. If the charging circuit malfunctions, even a brand-new battery will not deliver the expected runtime. A typical charging circuit contains a charge regulator IC (often a UC3906 or equivalent), a power MOSFET or bipolar transistor, a current-limiting resistor and a feedback loop with a voltage divider.
We diagnose charging circuits using precision oscilloscopy and voltage/current measurements. Common faults include: charge voltage too low (battery never fully charges), charge voltage too high (battery overheats and degrades prematurely), or zero charge current (complete charging circuit break). On APC Smart-UPS models the charge relays and current-sense resistors fail frequently. On Eaton units we sometimes find issues with the PFC (Power Factor Correction) stage, which affects both charging efficiency and output voltage quality. After component replacement and rework we run a full functional test — verifying the charge profile, switchover to battery mode and return to mains mode. UPS charging circuit repairs carry a 3-month warranty.
Pricing & warranty
Battery replacement warranty: 6 months.
If the repair cost changes during the process, the technician will call to agree on the new price. No work is done without your consent.
Frequently asked questions
Why customers choose SATER
- Custom-built battery assemblies. We design and assemble packs for the exact device — no 'close enough' substitutes.
- Sony, Samsung, LG, Panasonic, Molicel cells. Only top-tier cells — each one capacity-tested before assembly.
- Batteries for robots, power tools, laptops. We build packs for any device that runs on lithium batteries.
- 30+ years of experience. The service centre has been operating since 1993.
- We serve all of Latvia. Our service centre is in Riga and we accept devices from anywhere in the country.